Tension load cells for hoppers weighing, strength of linkage levers, and weigh scales, suspended weighing with ropes and rods etc.
Tension lead cell
Click to enlarge image
Material | Stainless steel |
Nominal load | 500, 750, 1000, 2000, 2500 kg |
Limit load | 150 % F.S. |
Breaking load | 300 % F.S. |
Supply voltage | Vcc 15 Max |
Output | 2 mV/V |
Output tollerance | 0,1 % F.S. |
Zero tollerance | 1 % F.S. |
Linearity | 0,03 % F.S. |
Hysteresis | 0,03 % F.S. |
Reapeatability | 0,03 % F.S. |
Input resistance | 380-386 ohm |
Output resistance | 350-353 ohm |
Insulation resistance | >= 2000 Mohm |
Creep (30 Minutes) | 0,03 % F.S. |
Thermal compensation | -10 / +40°C (14 / +104°F) |
Operating temperature | -20 / +70°C (-4 / +158°F) |
Temperature deviation zero | 0,003 % F.S. / °C |
Temperature deviation full scale | 0,002 % F.S. / °C |
Protection class | IP 68 |
Standard cable length | 5 m – 6 x 0,30 (shield not connected to the load cell body) |
Type | SHIELDED CABLE 6C R6 PVC 6X0,30 |
Length | 5 m (body lead cell not connected shield) |
Red | + IN |
Black | - IN |
Yellow | + REF |
Blue | - REF |
Green | + OUT |
White | - OUT |
General precautions to be followed in the installation and assembly of load cells: